Insulation

Insulation that is specified in interior systems is there generally for acoustical performance. The insulation is installed in the cavity created by the cold-formed steel framing. The insulation comes in three types of materials. They are glass fiber, mineral wool or spray-in foam insulation.

Note:  The limitations provided here are taken from appropriate building product manufacturer's source.  For more and the latest information relative to these limitations, it is recommended to contact either the representative association or a specific building product manufacturer.   A partial list of associations, and their links is provided on the home page of this site.

Cavity Insulation

Glass Fiber Insulation

Composition: Glass Fiber Batts
Size: 16" or 24" x 48" or 96"
Application: Cavity Installation
Compliance: ASTM C665, Type II, Class C, Category I Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction or Manufactured Housing
Limitations:
The National Electrical Code prohibits installation of insulation over or within 3" (76 mm) of recessed light fixtures, unless approved insulated ceiling (IC) lighting fixtures are used.
Kraft facing is flammable and should not be left exposed. It must be installed behind and in substantial contact with the unexposed surface of the ceiling, floor or wall finish. Special care should be taken when working with an open flame.
Insulation should be kept clean and dry at all times.
Installation: Manufacturer’s Installation Guidelines
Architectural Spec: 07 21 16 Blanket Insulation
More and Latest Information Link: www.naima.org

Mineral Insulation

Composition: non-combustible batts made from rock wool or slag comes with or without foil facing
Size: 16" or 24" x 48"
Application: Cavity Installation
Compliance: ASTM C665, Type II, Class C, Category I Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction or Manufactured Housing
Limitations:
The National Electrical Code prohibits installation of insulation over or within 3" (76 mm) of recessed light fixtures, unless approved insulated ceiling (IC) lighting fixtures are used.
Insulation should be kept clean and dry at all times.
Installation: Manufacturer’s Installation Guidelines
Architectural Spec: 07 21 16 Blanket Insulation
More and Latest Information Link: www.naima.org

Spray In Foam Insulation

Composition: Light density open or closed ceil water blown spray polyurethane
Size: Spray in open stud cavity
Application: Cavity Installation
Compliance: ASTM C1029 – Standard Specification for Spray-Applied Rigid Cellular Polyurethane Thermal Insulation
Limitations:
Not intended for exterior applications.
Not to be exposed to flames or where temperatures will exceed 240oF.
Insulation is combustible.
Requires 15 minute Thermal Barrier.
Installation: Manufacturer's Installation Guidelines
Architectural Spec: 07 21 19 Foamed-In-Place Insulation
More and Latest Information Link: Manufacturer’s website

 

While every effort has been made to ensure the accuracy of this information, we assume no liability for errors or omissions on these pages.  Please verify all information with the organizatons mentioned above.